HV LEAD ASSEMBLIES
50 KVDC

|
| L: |
To customer specification. |
| T: |
Standard termination is 3/8" strip and tin, but any desired termination/connector can be provided, including a molded head. |
| Tip: |
Designed to mate with LGH style 50KV receptacles or equivalent. Integral bond to cable insulation. |
| Materials |
| Nut: |
High Temperature (250° C) Standard Temperature(125° C) |
|
polyethermide resin polycarbonate |
| Washer: |
Teflon |
|
|
| Cable: |
Standard is 18 AWG copper wire, 19/30 silver plated strands, white silicone rubber insulation with a semi-conductor core. |
| Contact: |
Beryllium copper per QQ-C-530, gold plated per MIL-G-45204, Type II, Class 1. |
Molded Head: |
Silicone rubber per ZZ-R-765, Class I. |
| |
| |